China trusTec AC Motor - 120W 900RPM/3SPD Blower Motor For Air Conditioner
China trusTec AC Motor - 120W 900RPM/3SPD Blower Motor For Air Conditioner

  1. China trusTec AC Motor - 120W 900RPM/3SPD Blower Motor For Air Conditioner
  2. China trusTec AC Motor - 120W 900RPM/3SPD Blower Motor For Air Conditioner

trusTec AC Motor - 120W 900RPM/3SPD Blower Motor For Air Conditioner

  1. MOQ: 200 pcs
  2. Price: Negotiable (FOB/CNF/CIF)
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 100,000 pcs per month
Delivery Time 15 days fresh products after order confirmation.
Packaging Details Standard carton packing, foam board inside for protection.
Product Name 120W 900RPM/3SPD Blower Motor For Air Conditioner
Voltage 220V-240V
Speed 900RPM/3SPD
Output Power 120W
Brand Name trusTec
Model Number YDK-120-6B
Certification CE、High-tech Enterprise Certificate、ISO9000 Certificate 2023
Place of Origin Changzhou, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 100,000 pcs per month
Delivery Time 15 days fresh products after order confirmation. Packaging Details Standard carton packing, foam board inside for protection.
Product Name 120W 900RPM/3SPD Blower Motor For Air Conditioner Voltage 220V-240V
Speed 900RPM/3SPD Output Power 120W
Brand Name trusTec Model Number YDK-120-6B
Certification CE、High-tech Enterprise Certificate、ISO9000 Certificate 2023 Place of Origin Changzhou, China
High Light 900RPM Outdoor Fan Motor120W Outdoor Fan Motor3SPD Outdoor AC Motor

 

Product Name Blower Motor Voltage 220V-240V
Frequency 50 Hz Output Power 120W
Pole 6P AMPS 1.15A
Speed 900RPM/3SPD Capacitor 6μF/450V
Insulation Class Class B

Work Style

S1
Other protection THERMALLY PROTECTED

 

Ralated Outline

 

 

Key Parameters

Model

Power

/W

Frequency

/Hz

Speed

/RPM

Rated Current

/A

Voltage

/V

YDK-120-6B 120 50 900/3SPD 1.15 220-240

Ps:all dimension can be customized according to customer requirement.

 

trusTec AC Motor -  220-240V 50Hz 90W Air Conditioner Fan Motor

 

Product Features

1. Use NSK low noise high quality rolling bearing.

2. Small vibration,high efficiency .

3. Low temperature ,small vibration.

4. Advanced manufacturing equipment, skilled craftwork, high level of automatization, high quality insurance.

 

Product Applications

1. Air conditioner indoor / outdoor unit.

2. Air Purifiers, Air refresher.

3. Range hood, sewer grinder, dehumidifier, medical equipment, special blender etc.

 

FAQ

1.Where is your factory?
We are located at Changzhou city of China Jiangsu province, which is also called as motor producing base, the world's outstanding motor manufacturers sets factories here.

2. Can you provide the samples for evaluations before oders?
Nomally we provide each model 1 piece sample for free.

3. Are you a manufacturer or trading company?
We are a motor factory and in the industry for more than 10 years, you are welcomed to visit our factory anytime.

 

 

What are the 2 types of blower motor?

There are two main types of blower motors: single-speed motors and variable-speed motors. Single-speed blower motors blow air at one speed. Variable-speed motors adjust their speed to blow air at varying speed levels.

 

Key Signs of a Bad Blower Motor

 

While there are many problems that can crop up with your HVAC system, an issue with the blower motor can be easy to diagnose. Look for these key indicators that you have a bad blower motor.

 

Strange Rattling, Clanking, or Screeching

One of the first signs you may notice when there’s an issue with the blower motor is a strange noise coming from the indoor unit or air handler. Different noises will indicate different problems. For instance, a rattling could point to loose or broken parts while a screeching could mean it’s time to replace the motor belt.

 

Weak or No Airflow From The Vents

Since a blower motor’s whole job is to force air through your vents, a key sign it might be broken is if little to no airflow is coming from your vents. This issue might just as well be caused by a dirty air filter or closed vent but if you don’t notice any issues like that, you might want to investigate the blower motor.

 

A Sudden Spike in Your Energy Bills

It sucks, but if your blower motor isn’t properly distributing conditioned air throughout your home, your system will overcompensate to reach the temperature set on your thermostat. It will continue to kick out more and more heated or cooled air while your fan pushes it weakly through the vents. This will likely cause a significant increase in your energy bill.

 

An Overheating HVAC System

An overheating HVAC system is characterized by a burning smell and a system that won’t stay on. There are a lot of reasons why your HVAC system might overheat including dirty air filters, broken components, and age. If your blower motor starts to go out, it can cause the rest of the system to overwork and heat up.

 

 

What to Do When Your Blower Motor Goes Out

 

Since there are several issues that can cause a bad blower motor, there are a few avenues you can take to solve your problem. We recommend contacting your trusted HVAC specialist to get a better understanding of what the best course of action will be.

 

 

Replace or Maintain a Part in the Blower Motor

Sometimes the issue with your blower motor will be isolated to a single component within the part. You may simply need to replace the belt or lubricate the bearings. The issue could also be as easily resolved by clearing debris from in and around the blower motor.

 

 

Replacing the Blower Motor

If the whole motor is bad, you will need to replace it. There are a variety of models and brands to choose from when it comes time to select a blower motor. If you don’t select the right one for your system, you might inadvertently cause further damage down the line. This is why it’s important to consult an HVAC professional to assure you select the correct blower motor.

 

 

Keep Up With HVAC Maintenance

Regular HVAC maintenance can save you a lot of trouble. Once you solve the issue with your bad blower motor, be sure to have an HVAC specialist come once or twice a year to ensure everything is in working order. Some problems might arise without warning and cause costly issues if you don’t catch them early. HVAC maintenance can help you get ahead of any hidden problems.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2011

  • Total Annual:

    5 million-10 million

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Changzhou Trustec Company is working on the solutions supplier for the fan motors and the blower fans. We are capable of designing and producing the fan motors from diameter 3.3'' to 6.3'' and output power from 8W to 5KW. As the professional supplier for the fan motors and blow... Changzhou Trustec Company is working on the solutions supplier for the fan motors and the blower fans. We are capable of designing and producing the fan motors from diameter 3.3'' to 6.3'' and output power from 8W to 5KW. As the professional supplier for the fan motors and blow...

+ Read More

Get in touch with us

  • Reach Us
  • Changzhou Trustec Company Limited
  • NO.38 Hongye Road, New Northern District, Changzhou City,213033, Jiangsu Province, China
  • https://www.hvac-fanmotor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement