China O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring
China O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring

  1. China O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring
  2. China O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring
  3. China O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring

O2 Gas Analyzer With Electrochemical Sensor For Real Time Oxygen Monitoring

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Target Gas Oxygen
Supply Ability Supply Ability: >10000 Sets Per Year
type Oxygen Detector
Delivery Time appointed time
Alarm Mode Sound
Packaging Details Export Standard
Payment Terms L/C、D/A、D/P、T/T
Accuracy Class High Accuracy
Brand Name Runlai
Certification ISO certification
Place of Origin Xi'an, Shaanxi, China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Target Gas Oxygen Supply Ability Supply Ability: >10000 Sets Per Year
type Oxygen Detector Delivery Time appointed time
Alarm Mode Sound Packaging Details Export Standard
Payment Terms L/C、D/A、D/P、T/T Accuracy Class High Accuracy
Brand Name Runlai Certification ISO certification
Place of Origin Xi'an, Shaanxi, China
High Light Real Time O2 Gas Analyzer ,Electrochemical Oxygen Gas Analyser ,Monitoring Electrochemical Oxygen Analyzer

High Accuracy O2 Gas Analyzer with Electrochemical Sensor for Real-time Oxygen Monitoring

Product Specifications

Measurement Principle: Electrochemical

Measurement Range: 0~10/100/1000PPm (Range can be selected arbitrarily)

Accuracy: ≤±3%F.S (0~10PPm)

≤±2%F.S (0~100PPm)

≤±2%F.S (0~1000PPm)

Resolution: 0.1ppm/0.01ppm

Repeatability: ≤±1%F.S

Stability: Zero drift ≤±1%F.S/7d

Range drift ≤±1%F.S/7d

Response Time: T90≤10 S

Operating Voltage: 220-240VAC, 50\60Hz, 24VDC (Optional)

Digital Signal: Standard RS485 or RS232 communication port, enabling two-way communication with a computer

Analog Output: 4~20mA standard output signal, load resistance less than 500 ohms (0~10V optional)

Dimensions: 482mm (Width) ×136 mm (Height) ×370 mm (Depth)

Opening Size: 456mm (Width)×105mm (Height)

Inlet and Outlet: φ6 ferrule connectors (Customizable)

Ambient Temperature: -25℃~+55℃

Ambient Humidity: ≤90%RH

Inlet Pressure: 0.05 MPa≤Inlet Pressure

Sample Gas Flow Rate: 400ml/min

Measurement Principle: Electrochemical

The electrochemical principle is a detection method that determines the oxygen content in sample gas by reacting the electrolyte in the battery with oxygen molecules in the sample gas. Essentially, an oxygen sensor is an oxygen cell, with an oxygen electrode as the cathode and an appropriate metal as the anode. Since oxygen requires the metal to discharge, the cathode of this type of oxygen cell is typically silver, the anode is lead, and an electrolyte is charged inside. The electrolyte is separated from the sample gas by a membrane, allowing oxygen to pass through the membrane into the sensor while preventing the electrolyte from leaking out.

Key Features & Applications
  • Various instrument parameters can be configured, calibrated, and tested using a fully Chinese-titled touch menu. Historical records and curves can be set according to time for quick operations;
  • Displays measurement values, historical curves, range, status, and parameter setting interfaces simultaneously;
  • Uses imported sensors featuring high precision and fast response;
  • Automatic scheduled storage function during unattended operation, with stored data available at any time;
  • Built-in temperature compensation to minimize the impact of sample gas temperature and environmental changes on measurement accuracy;
  • 64MB memory and 128MB FLASH with USB interface for convenient data storage;
  • Ethernet port available for wide-area network connection (optional);
  • Features a new type of gas flow stabilization system with advantages including advanced technology, high precision, fast response, stable performance, comprehensive functionality, easy operation, and continuous gas analysis process;
  • Built-in vacuum pump (optional).
  • Online analysis of protective gases in air separation nitrogen production, storage, chemical processes, high-temperature sintering furnaces for magnetic materials, the electronics industry, as well as oxygen content in the glass and building materials industries.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2018

  • Total Annual:

    >Over 5 million dollars

  • Employee Number:

    >More than 150 peopl

  • Ecer Certification:

    Verified Supplier

Xi'an Runlai Instrument Co., Ltd. is a company specializing in the research, development, production, sales, and service of gas analysis technology and instruments. We have a team of professionals with long-term experience in gas analysis instrumentation, making us a technology-driven manufacturer... Xi'an Runlai Instrument Co., Ltd. is a company specializing in the research, development, production, sales, and service of gas analysis technology and instruments. We have a team of professionals with long-term experience in gas analysis instrumentation, making us a technology-driven manufacturer...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Runlai Instrument Co., Ltd.
  • Room 403, Building 3, Zhongxing Deep Blue Technology Industrial Park, Fengdong New City, Xi'an, Shaanxi Province
  • https://www.industrialgasanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement