Manufacturer of a wide range of products which include XLPE Insulated 4 Core Shielded Cable Copper Power ZR-YJV 4x300mm2 For Power Transmission,Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial,ZR...
MOQ: 1 Meter
Price:
| Payment Terms | L/C,T/T |
| Conductor nominal area (per core) | 300 mm² |
| Packaging Details | General Packaging or As Requirements |
| Conductor diameter (approx.) | 21.5–23.5 mm |
| Filler / binder | FR PP filler + FR tape |
| Cable shape | Round |
| Approx. weight | 9400 – 11500 kg/km |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Insulation thickness | 1.8 mm (300 mm² class) |
| Overall cable diameter | 55.0 – 64.0 mm |
| Design weight | ≈ 10000 kg/km |
| Supply Ability | 10000 meters per month |
| Number of cores | 4 |
| Conductor (×4) | Bare annealed copper, Class 2 stranded, commonly 61×∅2.52 mm (also 37×∅3.20 mm compact / 48×2.82 mm), conductor Ø ≈ 21.5–23.5 mm depending on compaction |
| Delivery Time | Less than 15 days |
| Conductor construction | Class 2, 61×∅2.52 mm,IEC 60228 / GB/T 3956, min. 15 wires |
| Insulation (×4) | XLPE |
| Design outer diameter | ≈ 59.0 mm |
| Diameter over insulated core | 24.9–26.9 mm,conductor + 2×1.8 |
| Sheath thickness | 2.6 mm |
MOQ: 1 Meter
Price:
| Conductor nominal area (per core) | 240 mm² |
| Packaging Details | General Packaging or As Requirements |
| Conductor diameter (approx.) | 19.0–21.0 mm |
| Filler / binder | FR PP filler + FR tape |
| Cable shape | Round |
| Approx. weight | 7600 – 9500 kg/km |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Supply Ability | 10000 meters per month |
| Insulation thickness | 1.7 mm (240 mm² class) |
| Overall cable diameter | 50.0 – 58.0 mm |
| Design weight | ≈ 8200 kg/km |
| Number of cores | 4 |
| Conductor (×4) | Bare annealed copper, Class 2 stranded, commonly 61×∅2.25 mm (also 37×∅2.87 mm compact / 48×2.52 mm), conductor Ø ≈ 19.0–21.0 mm depending on compaction |
| Conductor construction | Class 2, 61×∅2.25 mm,IEC 60228 / GB/T 3956, min. 15 wires |
| Payment Terms | L/C,T/T |
| Insulation (×4) | XLPE |
| Design outer diameter | ≈ 53.0 mm |
| Delivery Time | Less than 15 days |
| Diameter over insulated core | 22.4–24.4 mm,conductor + 2×1.7 |
| Sheath thickness | 2.5 mm (GB/T 12706 multi-core 185–300 mm² range) |
| Model Number | ZR-YJV 4*240mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TD |
| Place of Origin | China |
MOQ: 1 Meter
Price:
| Conductor nominal area | 185 mm² |
| Packaging Details | General Packaging or As Requirements |
| Conductor diameter | 16.8–18.5 mm |
| Filler / binder | FR PP filler + FR tape |
| Cable shape | Round |
| Approx. weight | 6200 – 7800 kg/km |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Supply Ability | 10000 meters per month |
| Insulation thickness | 1.6 mm (185 mm² class) |
| Overall cable diameter | 45.0 – 52.0 mm |
| Design weight | ≈ 6700 kg/km |
| Number of cores | 4 |
| Conductor (×4) | Bare annealed copper, Class 2 stranded, commonly 37×∅2.52 mm (also 19×∅3.55 mm compact / 36×2.55 mm), conductor Ø ≈ 16.8–18.5 mm depending on compaction |
| Conductor construction | Class 2, 37×∅2.52 mm,IEC 60228 / GB/T 3956, min. 15 wires |
| Payment Terms | L/C,T/T |
| Insulation (×4) | XLPE |
| Design outer diameter | ≈ 48.0 mm |
| Delivery Time | Less than 15 days |
| Diameter over insulated core | 20.0–21.7 mm,conductor + 2×1.6 |
| Sheath thickness | 2.4 mm (GB/T 12706 multi-core 150–300 mm² range) |
| Model Number | ZR-YJV 4*185mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TD |
| Place of Origin | China |
MOQ: 100 meters
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 7×∅1.04 mm, conductor Ø ≈ 3.1–3.4 mm |
| Overall cable diameter | 13.0 – 16.0 mm |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 3.1–3.4 mm |
| Sheath thickness | 1.5 mm (GB/T 12706 multi-core small section) |
| Filler / binder | FR PP filler + FR tape |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 7×∅1.04 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 5.5–5.9 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Approx. weight | 240 – 320 kg/km |
| Phase conductor nominal area | 10 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 7×∅1.35 mm, conductor Ø ≈ 4.1–4.5 mm |
| Design outer diameter | ≈ 14.5 mm |
| Neutral conductor nominal area | 6 mm² |
| Design weight | ≈ 275 kg/km |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 7×∅1.35 mm,IEC 60228 / GB/T 3956 |
| Diameter over neutral insulated core | 4.5–4.8 mm |
| Cable shape | Round |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 4.1–4.5 mm |
| Insulation thickness | 0.7 mm(Phase insulation and Neutral insulation) |
| Model Number | ZR-YJV 3x10mm²+1x6mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TD |
| Place of Origin | China |
MOQ: 100 meters
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 7×∅2.14 mm, conductor Ø ≈ 6.4–6.8 mm |
| Sheath thickness | 1.6 mm (GB/T 12706 multi-core 50–95 mm² range) |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 6.4–6.8 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Diameter over neutral insulated core | 8.2–8.6 mm |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 7×∅2.14 mm,IEC 60228 / GB/T 3956 |
| Neutral insulation thickness | 0.9 mm (25 mm² class) |
| Filler / binder | FR PP filler + FR tape |
| Design outer diameter | ≈ 23.0 mm |
| Phase conductor nominal area | 50 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 19×∅1.78 mm (also 7×∅3.00 mm compact), conductor Ø ≈ 9.0–9.5 mm depending on compaction |
| Overall cable diameter | 21.0 – 25.5 mm |
| Neutral conductor nominal area | 25 mm² |
| Approx. weight | 700 – 900 kg/km |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 19×∅1.78 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 11.0–11.5 mm |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 9.0–9.5 mm |
| Phase insulation thickness | 1.0 mm (50 mm² class) |
| Design weight | ≈ 770 kg/km |
| Model Number | ZR-YJV 3×50mm²+1×25mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TONGDU |
| Place of Origin | China |
MOQ: 100 meters
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 7×∅1.70 mm, conductor Ø ≈ 5.1–5.5 mm |
| Sheath thickness | 1.5 mm (GB/T 12706 multi-core 16–35 mm² range) |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 5.1–5.5 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Diameter over neutral insulated core | 6.5–6.9 mm |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 7×∅1.70 mm,IEC 60228 / GB/T 3956 |
| Neutral insulation thickness | 0.7 mm (16 mm² class) |
| Filler / binder | FR PP filler + FR tape |
| Design outer diameter | ≈ 19.5 mm |
| Phase conductor nominal area | 35 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 7×∅2.52 mm (also 19×∅1.53 mm compact), conductor Ø ≈ 7.6–8.0 mm depending on compaction |
| Overall cable diameter | 18.0 – 22.0 mm |
| Neutral conductor nominal area | 16 mm² |
| Approx. weight | 520 – 680 kg/km |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 7×∅2.52 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 9.4–9.8 mm |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 7.6–8.0 mm |
| Phase insulation thickness | 0.9 mm (35 mm² class) |
| Design weight | ≈ 585 kg/km |
| Model Number | ZR-YJV 3×35mm²+1×16mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TONGDU |
| Place of Origin | China |
MOQ: 100 meters
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 7×∅1.70 mm, conductor Ø ≈ 5.1–5.5 mm |
| Sheath thickness | 1.5 mm (GB/T 12706 multi-core 16–35 mm² range) |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 5.1–5.5 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Diameter over neutral insulated core | 6.5–6.9 mm |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 7×∅1.70 mm,IEC 60228 / GB/T 3956 |
| Neutral insulation thickness | 0.7 mm (16 mm² class) |
| Filler / binder | FR PP filler + FR tape |
| Design outer diameter | ≈ 18.0 mm |
| Phase conductor nominal area | 25 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 7×∅2.14 mm, conductor Ø ≈ 6.4–6.8 mm |
| Overall cable diameter | 16.5 – 20.0 mm |
| Neutral conductor nominal area | 16 mm² |
| Approx. weight | 430 – 560 kg/km |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 7×∅2.14 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 8.2–8.6 mm |
| Design weight | ≈ 480 kg/km |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 6.4–6.8 mm |
| Phase insulation thickness | 0.9 mm (25 mm² class) |
| Model Number | ZR-YJV 3x25mm²+1x16mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TD |
| Place of Origin | China |
MOQ: 100 meters
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 7×∅1.35 mm, conductor Ø ≈ 4.1–4.5 mm |
| Overall cable diameter | 14.5 – 17.5 mm |
| Insulation (×4) | XLPE |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 4.1–4.5 mm |
| Sheath thickness | 1.5 mm (GB/T 12706 multi-core small section) |
| Filler / binder | FR PP filler + FR tape |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 7×∅1.35 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 6.5–6.9 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Approx. weight | 320 – 420 kg/km |
| Phase conductor nominal area | 16 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 7×∅1.70 mm, conductor Ø ≈ 5.1–5.5 mm |
| Design outer diameter | ≈ 16.0 mm |
| Neutral conductor nominal area | 10 mm² |
| Design weight | ≈ 360 kg/km |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 7×∅1.70 mm,IEC 60228 / GB/T 3956 |
| Diameter over neutral insulated core | 5.5–5.9 mm |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 5.1–5.5 mm |
| Insulation thickness | 0.7 mm (16 mm² class) |
| Cable shape | Round |
| Model Number | ZR-YJV 3x16mm²+1x10mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TD |
| Place of Origin | China |
MOQ: 1 Meter
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 19×∅2.14 mm, conductor Ø ≈ 10.7–11.2 mm depending on compaction |
| Sheath thickness | 1.9 mm (GB/T 12706 multi-core 120–185 mm² range) |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 10.7–11.2 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Diameter over neutral insulated core | 12.9–13.4 mm |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 19×∅2.14 mm,IEC 60228 / GB/T 3956 |
| Neutral insulation thickness | 1.1 mm (70 mm² class) |
| Filler / binder | FR PP filler + FR tape |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 37×∅2.27 mm, conductor Ø ≈ 15.9–16.8 mm depending on compaction |
| Overall cable diameter | 34.5 – 41.0 mm |
| Neutral conductor nominal area | 70 mm² |
| Approx. weight | 1850 – 2300 kg/km |
| Design outer diameter | ≈ 37.0 mm |
| Phase conductor nominal area | 150 mm² |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 37×∅2.27 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 18.7–19.6 mm |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 15.9–16.8 mm |
| Phase insulation thickness | 1.4 mm (150 mm² class) |
| Design weight | ≈ 2050 kg/km |
| Cable shape | Round |
| Model Number | 3×150mm²+1×70mm² |
| Brand Name | TONGDU |
| Place of Origin | China |
| Certification | CE/ISO/CCC |
MOQ: 1 Meter
Price:
| Neutral conductor (×1) | Bare annealed copper, Class 2 stranded, 19×∅2.14 mm, conductor Ø ≈ 10.7–11.2 mm depending on compaction |
| Sheath thickness | 1.8 mm (GB/T 12706 multi-core 95–150 mm² range) |
| Packaging Details | General Packaging or As Requirements |
| Number of cores | 4 (3+1) |
| Neutral conductor diameter (approx.) | 10.7–11.2 mm |
| Outer sheath | Flame-retardant PVC (ZR grade) |
| Diameter over neutral insulated core | 12.9–13.4 mm |
| Insulation (×4) | XLPE |
| Supply Ability | 10000 meters per month |
| Neutral conductor construction | Class 2, 19×∅2.14 mm,IEC 60228 / GB/T 3956 |
| Neutral insulation thickness | 1.1 mm (70 mm² class) |
| Filler / binder | FR PP filler + FR tape |
| Phase conductor nominal area | 120 mm² |
| Phase conductor (×3) | Bare annealed copper, Class 2 stranded, 37×∅2.03 mm, conductor Ø ≈ 14.2–15.0 mm depending on compaction |
| Overall cable diameter | 31.0 – 37.0 mm |
| Neutral conductor nominal area | 70 mm² |
| Approx. weight | 1550 – 1950 kg/km |
| Design outer diameter | ≈ 33.5 mm |
| Payment Terms | L/C,T/T |
| Phase conductor construction | Class 2, 37×∅2.03 mm,IEC 60228 / GB/T 3956 |
| Diameter over phase insulated core | 16.6–17.4 mm |
| Delivery Time | Less than 15 days |
| Phase conductor diameter (approx.) | 14.2–15.0 mm |
| Phase insulation thickness | 1.2 mm (120 mm² class) |
| Design weight | ≈ 1710 kg/km |
| Cable shape | Round |
| Model Number | ZR-YJV 3×120mm²+1×70mm² |
| Certification | CE/ISO/CCC |
| Brand Name | TONGDU |
| Place of Origin | China |