| Packaging Details | Export plywood case with foam lining, actuator bolted to base plate |
| Positioning Accuracy | +/-0.5% of full stroke |
| Supply Ability | 100 Sets per Month |
| Delivery Time | 15-30 working days after confirmation |
| Position Feedback | 4-20mA DC |
| Payment Terms | T/T,L/C,Western Union |
| Power Supply | AC220V 50/60Hz or DC24V |
| Output Torque | 50 - 2000 Nm |
| Ambient Temperature | -25 to +70 deg C |
| Communication | Modbus RTU optional |
| Protection Class | IP65/IP67 |
| Input Signal | 4-20mA or 0-10V DC |
| Display | Local LCD with keypad and diagnostics |
| Deadband | 0.5% - 3.0% adjustable |
| Brand Name | QINWEIYB |
| Certification | ISO 9001:2015, CE |
| Place of Origin | China |
| Model Number | QW-DMT156 |
View Detail Information
Explore similar products
Explosion Proof Electric Actuator Ex d IIC T6 2000Nm for Hazardous Area Valves
Linear Electric Actuator 50 kN Thrust 100 mm Stroke for Globe Control Valves
Industrial Multi-Turn Electric Actuator 4000 Nm AC380V ISO 5210 for Gate Globe
Quarter Turn Electric Actuator 3000 Nm AC220V DC24V ISO 5211 for Ball Butterfly
Product Specification
| Packaging Details | Export plywood case with foam lining, actuator bolted to base plate | Positioning Accuracy | +/-0.5% of full stroke |
| Supply Ability | 100 Sets per Month | Delivery Time | 15-30 working days after confirmation |
| Position Feedback | 4-20mA DC | Payment Terms | T/T,L/C,Western Union |
| Power Supply | AC220V 50/60Hz or DC24V | Output Torque | 50 - 2000 Nm |
| Ambient Temperature | -25 to +70 deg C | Communication | Modbus RTU optional |
| Protection Class | IP65/IP67 | Input Signal | 4-20mA or 0-10V DC |
| Display | Local LCD with keypad and diagnostics | Deadband | 0.5% - 3.0% adjustable |
| Brand Name | QINWEIYB | Certification | ISO 9001:2015, CE |
| Place of Origin | China | Model Number | QW-DMT156 |
| High Light | Intelligent modulating actuator 4-20mA control ,PID positioning actuator 2000 Nm ,Modbus RTU process valve actuator | ||
When a process demands a valve that stops exactly where the controller asks — 43% open, not "roughly half" — an on/off actuator is the wrong tool. This intelligent modulating electric actuator accepts a 4–20 mA or 0–10 V setpoint, positions the valve to within ±0.5%, and reports actual position back to your DCS or PLC. Built-in PID logic, configurable signal-loss action and an optional Modbus RTU interface make it a complete final control element for flow, pressure, level and temperature loops.
Open/close valves create oscillation, not control. In a flow or pressure loop, the control system constantly asks for small corrections; if the valve can only slam fully open or fully closed, the process overshoots, quality drifts and energy is wasted. A modulating actuator holds any intermediate position accurately and moves smoothly between setpoints, which is exactly what a PID controller needs to stabilize the loop. Without it, your control strategy is only as good as the weakest link — and a coarse valve makes an expensive transmitter and controller useless.
Modulating duty is also mechanically demanding: the motor starts and reverses far more often than in on/off service, so the drive train and thermal protection must be rated for it. The table below compares four control scenarios and the failure modes that appear when the final control element cannot follow the setpoint.
| Operating Condition | Typical Pain Point | Risk If Left Unattended | How This Actuator Helps |
|---|---|---|---|
| Flow or pressure loops needing fine throttling | On/off valve causes cycling; manual throttling drifts with load | Product quality variation, pump wear, energy loss | Continuous positioning to ±0.5% with adjustable deadband for stable loops |
| Batch or dosing processes with changing setpoints | Slow, imprecise valve response to new setpoints | Batch over/under-dosing, scrap batches | Fast, repeatable repositioning driven by built-in control logic |
| Signal loss or power dip during operation | Valve freezes at last position or moves unpredictably | Unsafe process state, pressure excursions | Configurable fail-safe action: hold, open or close to a preset position |
| DCS/PLC supervision and diagnostics | No position feedback, no fault visibility, manual checks | Hidden failures, unscheduled downtime | 4–20 mA feedback standard, Modbus RTU option, local LCD diagnostics |
The actuator compares the incoming 4–20 mA or 0–10 V setpoint with the actual valve position, measured by a precision feedback element coupled to the output shaft. An internal controller drives the motor forward or reverse until the error between setpoint and position falls inside the programmed deadband, then stops. Because the comparison happens continuously inside the actuator, the valve tracks the setpoint even if the DCS updates slowly, and the loop gains smoother response than a system that relies on external switching.
The integrated positioner replaces the separate positioner-and-actuator combination used on pneumatic valves, removing air supply, I/P converters and calibration drift. Local controls on the LCD panel allow manual positioning, deadband and travel limit adjustment, and signal-loss behavior selection (hold last position, open, close, or move to a preset percentage). Optional Modbus RTU communication provides remote setpoint, position readback and fault status over a simple two-wire bus.
Integration follows three steps. First, wire the loop: two wires for the 4–20 mA setpoint from the DCS/PLC analog output, two wires for the 4–20 mA position feedback to the analog input, plus power. Second, configure the actuator: set travel limits, deadband, direction of action (direct or reverse) and signal-loss behavior from the local panel. Third, tune the loop: start with a deadband of 1–2% and observe cycling; widen the deadband if the valve hunts, narrow it if the process demands finer control. The table below shows typical configurations by loop type.
| Control Loop | Typical Valve Type | Recommended Configuration |
|---|---|---|
| Flow control (dosing, blending) | Globe or ball control valve | 4–20 mA setpoint, 1% deadband, hold on signal loss |
| Pressure control (steam, gas) | Globe valve, cage-guided | Reverse action, 0.5–1% deadband, close on signal loss |
| Level control (tanks, drums) | Butterfly or globe valve | Slow stroke setting, 2% deadband, preset 50% on signal loss |
| Temperature control (heat exchangers) | Butterfly valve on hot medium | 4–20 mA setpoint, Modbus readback for trend logging |
This modulating actuator is used wherever a control valve must track a process setpoint continuously and reliably.
| Field | Details |
|---|---|
| Project type & industry | Water treatment chemical dosing system (Southeast Asia) |
| Valve type & size | Globe control valve, DN50, PN16 |
| Media & temperature | Polymer dosing solution, ambient temperature |
| Line pressure | 0.4–0.6 MPa |
| Previous operation mode | Manual needle valve, adjusted by operator rounds |
| Actuator model | QW-DMT156, 300 Nm, AC220V |
| Control signal | 4–20 mA from flow-proportional PLC setpoint |
| Feedback | 4–20 mA actual position to PLC |
| Installation environment | Indoor chemical room, ventilated, 35°C max |
| Result | Dosing follows water flow within 2% accuracy; chemical consumption reduced approximately 15% |
| Field | Details |
|---|---|
| Project type & industry | Food processing plant utility boiler house |
| Valve type & size | Balanced globe control valve, DN80, PN25 |
| Media & temperature | Saturated steam, up to 180°C upstream |
| Line pressure | 1.0 MPa inlet to 0.4 MPa outlet |
| Previous operation mode | Self-acting mechanical regulator with visible hunting |
| Actuator model | QW-DMT156, 800 Nm, AC220V, Modbus RTU |
| Control signal | 4–20 mA from pressure transmitter PID loop |
| Feedback | Position readback via Modbus to boiler DCS |
| Installation environment | Indoor, high ambient heat near steam lines |
| Result | Downstream pressure held within ±0.01 MPa; hunting eliminated and steam waste reduced |
| Parameter | Specification |
|---|---|
| Input signal | 4–20 mA or 0–10 V DC (selectable) |
| Positioning accuracy | ±0.5% of full stroke |
| Position feedback | 4–20 mA DC (load ≤ 500 Ω) |
| Deadband | Adjustable 0.5% – 3.0% |
| Output torque | 50 – 2000 Nm (model dependent) |
| Power supply | AC220V 50/60Hz or DC24V |
| Communication | Modbus RTU (optional) |
| Protection class | IP65 / IP67 |
| Ambient temperature | -25°C to +70°C |
| Display | Local LCD with keypad, fault diagnostics |
An on/off actuator drives the valve to one of two positions and stops at mechanical limits; it is designed for isolation duty with infrequent operation. A modulating actuator moves the valve to any position requested by an analog setpoint and holds it there, with a motor and gear train rated for frequent starts, stops and reversals. The control electronics compare setpoint against actual position continuously, so the valve can track a slowly changing process demand. If you install an on/off actuator in a throttling service, the motor overheats and the process oscillates; choose the modulating type whenever the valve must hold intermediate positions.
The behavior is fully configurable and set during commissioning. The standard options are: hold the last position, drive fully open, drive fully closed, or move to a preset percentage such as 50%. Choose the action that matches your process safety analysis — for example, close on signal loss for a steam valve, but hold position for a flow-balancing valve where sudden closure could cause water hammer. The selected behavior is stored in non-volatile memory, so the actuator remembers it after a power cycle. We configure the action to your specification before shipment if you state it when ordering.
Yes, and this is one of the most common conversions. Electric modulating actuators remove the need for instrument air, I/P converters, air filter regulators and pneumatic tubing, which lowers installation and maintenance cost and improves reliability in plants without reliable air supply. The 4–20 mA setpoint wiring is identical to what your DCS already provides, so the control loop configuration does not change. Before conversion, confirm that the electric actuator torque and stroke time meet the valve requirement, and that the mounting flange matches. We can supply adapter kits for common pneumatic actuator topworks.
The Modbus RTU option provides a standard RS-485 two-wire interface with configurable slave address, baud rate and parity. Through the bus you can write the setpoint, read actual position, read fault and status registers, and issue manual commands. The register map is documented in the manual, and our engineers can supply a sample configuration for common PLC brands. For new plants, this removes analog wiring entirely and gives maintenance staff remote diagnostics. If your system uses Profibus or another protocol, tell us when ordering so we can advise on available gateway options.
Modulating actuators work hardest, so follow a simple schedule: every 6 months, check cable glands, terminal tightness and the local display for fault codes; every 12 months, verify that the feedback signal at the DCS matches the local position indication and confirm the deadband setting has not drifted. The gear box is factory-lubricated for life on most models, so no routine oil change is needed. If the valve operates in a dusty environment, keep the housing fins and indicator window clean for heat dissipation. With this routine, modulating actuators typically run for years without intervention; stroke counters in the diagnostics help you plan proactive servicing.
Yes. A manual override allows the valve to be positioned by hand when power is off, which is essential during installation, stroke setting and emergency situations. The override is mechanically interlocked so that motor operation resumes safely when power returns. During commissioning, use the manual mode to confirm the full travel range and set the limit positions before switching to automatic. For battery-backed fail-safe requirements, discuss the DC24V version with an optional backup arrangement; the standard AC version is intended for plants with continuous power and a manual override for outages.
QINWEIYB builds modulating actuators for engineers who cannot tolerate sloppy final control elements. Each actuator is calibrated against a certified 4–20 mA source and stroke-tested under load in our ISO 9001 certified factory before dispatch, and the calibration certificate is included. Our application engineers help you select torque class, configure signal-loss action and even suggest loop tuning starting points from your process description. You buy directly from the manufacturer, with responsive spare parts supply and a clear warranty on manufacturing defects.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Year Established:
Establishe
Total Annual:
5 million-10 million
Employee Number:
500~800
Ecer Certification:
Verified Supplier
Our company adheres to the business philosophy of "treating people with sincerity and establishing the enterprise with integrity", emphasizing the development of the enterprise, customer-oriented, quality first, and striving for excellence. In the field of industrial automation instruments and met... Our company adheres to the business philosophy of "treating people with sincerity and establishing the enterprise with integrity", emphasizing the development of the enterprise, customer-oriented, quality first, and striving for excellence. In the field of industrial automation instruments and met...
Get in touch with us
Leave a Message, we will call you back quickly!