| Battery Bank Architecture | Modular Rack - Based Energy Storage |
| Recommended Deployment | Dedicated Indoor Technical Area |
| Capacity Selection Basis | Daily Energy Use and Backup Requirement |
| System Supply Scope | Battery Bank without PCS or Solar Array |
| Supply Ability | 5000 Units per Month |
| Storage Project Segment | 200kWh Commercial Battery System |
| PCS Arrangement | Separate High-Voltage PCS Required |
| Main Energy Application | Solar Storage and Load Management |
| Packaging Details | Heavy-Duty Wooden Case with Protective Foam |
| Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production |
| Payment Terms | L/C,T/T,Western Union |
| Backup Planning Level | Commercial and Industrial Energy Reserve |
| Certification | CE , MSDS , UN38.3 |
| Place of Origin | China |
| Brand Name | Voltertech |
| Model Number | BAT-200KWH-640V-RM-Q |
View Detail Information
Explore similar products
100.35kWh 358.4V LiFePO4 High Voltage Battery System With Rack Design
20.48kWh Modular Battery Backup 224V HV Battery System With Four Rack Modules
30.72kWh 336V High Voltage Battery System With Six Modular Rack Units
40.96kWh 448V Modular High Voltage Battery System With Eight Rack Modules
Product Specification
| Battery Bank Architecture | Modular Rack - Based Energy Storage | Recommended Deployment | Dedicated Indoor Technical Area |
| Capacity Selection Basis | Daily Energy Use and Backup Requirement | System Supply Scope | Battery Bank without PCS or Solar Array |
| Supply Ability | 5000 Units per Month | Storage Project Segment | 200kWh Commercial Battery System |
| PCS Arrangement | Separate High-Voltage PCS Required | Main Energy Application | Solar Storage and Load Management |
| Packaging Details | Heavy-Duty Wooden Case with Protective Foam | Delivery Time | 10-15 Days for Samples; 30-40 Days for Bulk Production |
| Payment Terms | L/C,T/T,Western Union | Backup Planning Level | Commercial and Industrial Energy Reserve |
| Certification | CE , MSDS , UN38.3 | Place of Origin | China |
| Brand Name | Voltertech | Model Number | BAT-200KWH-640V-RM-Q |
| High Light | Commercial LiFePO4 Battery System ,High Voltage LiFePO4 Battery System ,LiFePO4 Battery System 640V | ||
200.96kWh 640V High Voltage LiFePO4 Battery System with Rack Design
This high voltage LiFePO4 battery system provides 200.96kWh of nominal energy from a 640V 314Ah battery configuration. It is designed as the DC energy-storage section of compatible commercial solar, load-management and backup power projects.
The battery bank uses ten rack-mounted units, allowing the complete storage capacity to be organized within a modular project layout. A compatible high-voltage PCS, external DC protection, energy-management equipment and project wiring are selected separately.
The 200.96kWh rating represents nominal stored DC energy. This capacity can be evaluated for factories, commercial buildings, agricultural facilities and other project-based energy systems that require a larger energy reserve.
Battery energy and PCS output power should be calculated separately. The battery determines how much energy can be stored, while the PCS determines the available AC output, charging power and system operating strategy.
Solar Energy Storage
Store part of the available solar generation for later use when project consumption continues after the main production period.
Load Management
Use stored energy according to the project load profile and the operating strategy configured through the external PCS or EMS.
Backup Energy Reserve
Maintain a planned energy reserve for selected commercial or industrial loads when backup operation is required.
The complete battery bank consists of ten rack-mounted units. Each unit measures 890 × 440 × 240mm and has a net weight of 118kg.
The modular format allows individual battery units to be positioned within the planned rack or battery-room arrangement. The supporting structure, floor loading, access route and available service space should be reviewed according to the complete project layout.
The IP20 enclosure requires a dry indoor technical area protected from rain and condensation. The installation location should also provide suitable ventilation, controlled access and space for cables and external protection equipment.
The selected PCS must support the complete 580–700Vdc battery operating range. Checking only the nominal 640V value is not sufficient because the battery voltage changes during charging and discharging.
The maximum continuous charging current and maximum continuous discharge current are both 200A. Actual PCS current settings can be lower according to the required system power, cable design and charging strategy.
A maximum pulse-discharge current of 300A is listed in the specification. Because no pulse duration is stated, it should not be treated as the normal continuous operating current.
Optional CAN or RS485 communication can be configured for compatible PCS equipment. An optional LCD provides access to supported local battery information. Compatibility should be confirmed according to the selected PCS model.
The product is the high-voltage battery bank only. The PCS, EMS, solar array, switchgear, cooling design and site-level electrical system are separate project components.
| Battery System Configuration | Ten Rack-Mounted LiFePO4 Battery Units |
| Nominal Electrical Rating | 640V / 314Ah / 200.96kWh |
| Battery Operating Range | 580–700Vdc |
| Floating-Charge Voltage | 700Vdc |
| Charge and Discharge Current | 200A Continuous / 300A Maximum Pulse Discharge |
| Optional Communication and Display | CAN / RS485 / LCD |
| Battery Protection Functions | Overcharge / Overdischarge / Overcurrent / Short Circuit / Overtemperature |
| Unit Dimensions and Weight | 890 × 440 × 240mm / 118kg Net per Unit / 10 Units |
| Operating Environment | IP20 / -10°C to 50°C / 0–95% Non-Condensing / ≤1500m |
No. It is the battery-storage section. The PCS, EMS, switchgear and solar equipment are selected separately.
No. The PCS must support the complete 580–700Vdc range and the required battery current.
They are listed as optional configurations and should be confirmed when the project specification is prepared.
The IP20 battery system requires a dry indoor technical location.
Provide the daily energy profile, peak load, backup requirement, PCS specification and available installation space.
Planning a commercial high-voltage energy storage project?
Company Details
Business Type:
Manufacturer
Year Established:
15 Years
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
/* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width... /* ========================================= VOLTERTECH ABOUT US Lightweight responsive version Primary: #4E2F18 Accent: #D6AF88 ========================================= */ .vt-about-page, .vt-about-page * { box-sizing: border-box; } .vt-about-page { width...
Get in touch with us
Leave a Message, we will call you back quickly!